AI Capacitive Fuel Level Sensor (RS-485)
Key specifications
All specs- Mean time between failures
- 100 000 hours
- Platform
- KO Fleetz platform via a supported GPS tracker
- Output
- RS-485
- Current
- Max. 40 mA (0.4 W)
- Operating temperature
- -40 °C to +80 °C
- Included
- Sensor, flange seal, installation kit (gasket, rivet nuts, bolts, washers, screws, 1 A fuse and holder, crimp connectors, security seal), mounting cable, sealant, gloves, manual
- Custom quoteTailored to your fleet, with GST invoice
- InstallationFitted and commissioned at your depot
- Pan-India supplyShipped to your depot, anywhere in India
Our most advanced capacitive fuel level sensor. Built-in AI analyses and refines the fuel level signal in real time – trained on data from monitored vehicles – so readings stay smooth on rough roads and sloshing tanks. That lets you set very small thresholds and still catch every refuelling and every fuel drain, without false alarms.
Key features
- Built-in AI refines fuel level data in real time for smooth, accurate readings
- Detects refuelling and fuel drains with minimal thresholds – no false alarms from fuel sloshing
- Automatically adapts when fuel properties change (different stations, summer / winter diesel)
- Dual measuring elements in one sensor; self-cleaning probe design – no manual washing
- ± 0.5% accuracy; lengths from 700 to 3000 mm (cut to tank depth)
- IP69K monolithic, vandal-resistant body
- RS-485 with Modbus RTU and the industry-standard fuel sensor protocol supported by most GPS trackers (auto-detected); built-in accelerometer
- Wide 7–75 V supply with 2500 V galvanic isolation and wiring-error protection
- Fuel level, refuelling and drain events on the KO Fleetz platform via a supported GPS tracker
Use cases
Fuel-theft preventionCatch even small drains that ordinary sensors miss.
Trucks & busesAccurate fuel use per trip and instant refuelling / drain alerts.
Generators & DG setsRemote fuel level and theft detection for gensets and towers.
Construction & mining machinesFuel use per engine hour on site.
Works with
- KOF-FLS-01 – Self-Calibrating Capacitive Fuel Level Sensor (RS-232 / RS-485)
- KOF-FLS-EX-01 – Explosion-Proof Fuel Level Sensor (ATEX Zone 0)
Need help choosing? Tell us your vehicle types and fleet size — we'll recommend the right combination and send a tailored quote. Request a quote or call +91 80566 86222.
See the Specification tab for full technical details.
| General | |
| Mean time between failures | 100 000 hours |
| Design service life | 8 years |
| Connectivity | |
| Platform | KO Fleetz platform via a supported GPS tracker |
| Interfaces | |
| Output | RS-485 |
| Protocols | Modbus RTU + industry-standard fuel sensor protocol (automatic detection) |
| Baud rate | 1200 – 115 200 bit/s (default 19 200) |
| Network address | 1 – 254 |
| Power | |
| Current | Max. 40 mA (0.4 W) |
| Supply voltage | 7 – 75 V |
| Galvanic isolation | 2500 V |
| Physical & Environment | |
| Operating temperature | -40 °C to +80 °C |
| Ingress protection | IP69K |
| Dimensions | 87.3 × 83.5 × (21 + measuring length) mm |
| Humidity | Up to 100% |
| Body | Monolithic, vandal-resistant; dual measuring elements |
| In the Box | |
| Included | Sensor, flange seal, installation kit (gasket, rivet nuts, bolts, washers, screws, 1 A fuse and holder, crimp connectors, security seal), mounting cable, sealant, gloves, manual |
| Measurement | |
| Measuring length | 700, 1000, 1500, 2000, 2500, 3000 mm |
| Accuracy | ± 0.5% |
| Output range | 0 – 4095 (12-bit digital code) |
| Measurement period | 1 second |
| Automatic data output | Every 1 – 255 seconds (configurable) |
| Fuel temperature measurement | -40 °C to +80 °C |
| Fuel types | Petrol, summer and winter diesel, other light petroleum products |
| Motion sensor | Built-in accelerometer |